Oxygen Bomb Calorimeter XRY-1A

Oxygen Bomb Calorimeter XRY-1A

Oxygen Bomb Calorimeter XRY-1A

1. Adopting a self sealing oxygen bomb, the entire structure is made of stainless steel, with sufficient strength to withstand the maximum pressure generated during solid combustion (60-70 atmospheres), and to withstand even greater pressure generated by liquid fuel.
2. The inner water tank is made of stainless steel sheet with a pear shaped cross-section. The water tank has a capacity of 3000 grams and is equipped with an electric stirrer to ensure uniform temperature of the water bath inside.
3. The outer water jacket is welded from a stainless steel double-layer container. During the experiment, it is filled with water and the water temperature inside the cylinder is uniformly adjusted using a water jacket stirrer to create a constant temperature environment that meets the test requirements.

 

Working power AC (220 ± 10%) V, 50Hz, wide voltage adaptability, compatible with conventional civilian and laboratory power supply environments, no need for dedicated power supply lines
Total power consumption ≤150W, Low power design, low energy consumption for long-term operation, and low load pressure on laboratory circuits
Thermal capacity (14000~15000)J/K, The thermal capacity range is suitable for the calorific value determination needs of most solid or liquid samples, without the need for frequent calibration adjustments
Temperature resolution 0.001K, The temperature sensing accuracy is extremely high, which can capture small temperature changes and provide accurate data support for calorific value calculation
Calorific value error ≤60J/g, The measurement error of calorific value is small, and the accuracy of the results is high, which meets the requirements of high-precision calorific value testing scenarios
Temperature  range (10-35) ℃, covering the temperature range of conventional laboratory environments, suitable for core temperature measurement needs
Repeatability error ≤ 0.2% (Class C), small deviation in multiple parallel test data, strong stability of results, meeting industry repeatability standards
Oxygen bomb pressure resistance 20MPa, Oxygen bombs have strong pressure bearing capacity and can safely withstand the high-pressure environment during sample combustion, ensuring the safety of test operations
Environmental temperature (15-28) ℃, and the temperature fluctuation during one measurement process should not exceed ± 1 ℃. It is necessary to control the stable ambient temperature to avoid affecting the testing accuracy
Store temperature measurement data Can store 60 temperature measurement data, facilitating subsequent data traceability, organization, and analysis, reducing manual recording workload
Relative humidity ≤ 85%, it should be used within this humidity range to prevent damage to the instrument circuit or affect component performance in humid environments
Dimensions 600mm x 460mm x 430mm(L*W*H), with moderate volume, occupying less laboratory countertop space, and easy to place and operate